Pressure on 410a refrigerant

In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...

Pressure on 410a refrigerant. In this HVAC Training Video, I Show 4 Examples of Checking the R410A Refrigerant Charge Levels on Air Conditioners. We Measure the R-410A Pressures, Saturate...

Water-cooled systems utilizing R410a refrigerant demand special regulating valves first introduced by Metrex Valve in 2000. Higher system pressures also make longer pipe separations achievable. Compressor displacement decreases by 30% and the heat transfer ratio improves by 35%. This allows for the use of smaller physical size system-components ...

The big debate in the HVACR industry right now is which refrigerant(s) will be chosen to replace R-410A in many types of comfort cooling equipment. Countries around the globe are already phasing down HFCs, and various states in the U.S. are passing legislation that would also minimize the use of these high-GWP refrigerants. California … Eco-Safe R-410A Refrigerant & MrCool. August 10, 2016. By MR COOL. Eco-safe R-410A refrigerant is the new standard for American air conditioners and heat pumps. As you might expect, it’s also the main refrigerant we use here at MrCool. The government, of course, required companies like us to adopt refrigerants like R-410A, but do you know why? The primary reasons for doing this are simple. One, if you recharge the refrigerant at incorrect pressure and temperature, some of your system components may fail. ... it has a lower global warming potential than R-410A. 407C has a GWP of 1774, while 410A is at 2088. The refrigerant is also safe to use if you use the proper procedure …The 410A Pressure-Temperature Calculator is a powerful tool for HVAC professionals, enabling quick and accurate pressure calculations for the R-410A refrigerant. By simplifying complex calculations, it aids in the design, maintenance, and troubleshooting of HVAC systems, ensuring they operate efficiently and effectively.410A refrigerant (ASHRAE designation: R-410A [50/50]), have been developed and are presented here. These tables are based on extensive experimental measurements. Equations have been developed, based on the Martin-Hou equation of state, which represent the data with accuracy and consistency throughout the entire range ofsystem charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3.Your refrigerator is arguably the most important appliance in your kitchen, which makes buying a new one a potentially stressful process. Luckily, Real Simple has created an handy ...R‐410A. Version 2.5 Revision Date 04/18/2022 Document 10005001 . Page 1 of 8 SECTION 1 ‐ CHEMICAL PRODUCT AND COMPANY IDENTIFICATION . PRODUCT NAME : R‐410A OTHER NAME : Difluoromethane, Pentafluoroethane PRODUCT USE : Refrigerant gas, for professional use only Restrictions : Do not use product for anything …

developments. Today, the air conditioning market is facing tough government pressure on energy savings and environment restrictions. R410A being a non-ozone depleting chemical able to improve energy e˝ciency, it is now proven that it will be the long-term replace-ment to HCFC refrigerants. developments. Today, the air conditioning market is facing tough government pressure on energy savings and environment restrictions. R410A being a non-ozone depleting chemical able to improve energy e˝ciency, it is now proven that it will be the long-term replace-ment to HCFC refrigerants.FreonTM 410A has higher operating pressures compared to R-22. FreonTM 410A is for new equipment that is specifically designed for R-410A. FreonTM 410A will require use …One of those major changes is the R410-a phase out, and the adoption of new refrigerant standards in 2023. In this article, we discuss all the refrigerant changes set to take effect in 2023. The US Environmental Protection Agency (EPA) will begin the first part of the HFC phase out based on the American Innovation & Manufacturing (AIM) Act ...R-410A refrigerant costs approximately $8 to $12 per pound or about $200 to $300 per 25-pound container. Starting in 2020, the EPA banned the import and purchase of R-22 Freon. If you have an older unit that takes R-22 refrigerant, you can’t simply add R-410A because of the pressure differences between the two products.Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...

Have you noticed your milk getting frosty? Meat spoiling quickly? It’s likely your refrigerator is set to the wrong temperature. The FDA recommends keeping your refrigerator at or ...All welded OEM pressure transmitter for use on refrigeration application with R22 and R410A refrigerant up to 400 psig. 17.609G Pressure Transmitter. 17-609G data sheet; Pressure Range: 0 – 400 psi g; Output: 4 – 20mA / 2 wire; Supply Voltage: 8 – 32V dc; Electrical Connection: Male & female plug ISO 4400OPERATING PRESSURE POINTS “Systems using R-410A operate at higher pressures [than R-22],” points out the Field Diagnostics team. “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 system, while they would be 133 and 406 psia, respectively, in an R-410A ...R-32 Refrigerant. R-410A is a perfectly good refrigerant, but there’s a new product on the market: R-32 coolant. R-32 has only one-third of the GWP than R-410A, uses 20% less refrigerant, is easier to recycle, and is more efficient. These qualities make it an even more environmentally-friendly alternative for keeping your home comfortably cool.This is a Step by Step Process (In Real-time) of Adding R-410A Refrigerant into a System that is a little Undercharged! We use the Subcooling Process to show you how far the Charge is off and Exactly what we need to do to Add Refrigerant and How to Verify that we have the Correct Charge once we are complete. Support-Tool List-

Harrison county wv 911.

Freon™ 410A (R-410A) refrigerant offers higher cooling capacity and significantly higher pressure than R-22 for use in systems specifically designed for R-410A.Table of Contents. Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, R410A is … R410A Refrigerant. R410A, often known as Puron, is an industry mainstay. But it’s been under scrutiny due to its high GWP. Overview and Use. R410A is a common refrigerant in residential and commercial AC units. Despite its environmental impact, it’s still a go-to for many HVAC systems due to its performance and non-flammability. Pros Because R-410A differs from R-22 in several respects, including operating pressure, some trade schools offered classes and certifications for R-410A specifically. These are not equivalent to a section 608 certification.Saturation Pressure-Temperature Data for R410A (psig)*. Temp (°F) Pressure. Temp (°C) Temp (°F) Pressure.

Water-cooled systems utilizing R410a refrigerant demand special regulating valves first introduced by Metrex Valve in 2000. Higher system pressures also make longer pipe separations achievable. Compressor displacement decreases by 30% and the heat transfer ratio improves by 35%. This allows for the use of smaller physical size system-components ... In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...Unlike the shift from R-22 to R-410A, we’ll start using refrigerants that have chemical properties that are very similar to R-410A. Credit: The Chemours Company The discharge temperatures of R-32 will be a little higher and call for a thicker oil (POE-46), but the system pressures, temperatures, and efficiencies are all very similar.Refrigerant Pressure-Temperature Home Back. Choose Refrigerant: R-410A R-22 °C °F: Psig-40-39-38-37-36 ...R32 is a single compound, while R410A is made from a mixture of R32 and R125. R410A has high pressure making it difficult to handle. R32 has higher cooling efficiency. In AC gas refilling, less R32 is required than R410A. R32 is moderately more flammable than R410A. What are the Advantages of Switching to R32. More efficient.The experimental apparatus established in the present study, as schematically shown in Fig. 1, to investigate the condensation heat transfer and associated frictional pressure drop of refrigerant R-410A in a vertical PHE consists of four independent loops and a data acquisition system.It includes a refrigerant loop, two …This article refers to troubleshooting refrigerant charge on 410a and R22 residential air conditioning systems. Although many of the principles will carry over to other types of refrigerants and drop-ins. ... R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply ...REFRIGERANT PRESSURE / TEMPERATURE CHARTS for R-22, R-410A, R-134A, R-404A REFRIGERANTS [PDF] Advantage Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142USA, Tel: 317-887-0729 Web site: www.AdvantageEngineering.com Email: [email protected] sure. R-410A is a higher-pressure refrigerant than R-22 and should be used only in equipment specifically designed for R-410A. R-410A systems can be designed to provide higher energy efficiency than R-22 and will meet and exceed U.S. Department of Energy efficiency guide-lines. Equipment designed for R-410A has up to 60 percent greater capacity November 2, 2003. Several major manufacturers are producing comfort air conditioning equipment using refrigerant 410A. The trend towards the use of R-410A continues to grow and there is a demand for technicians who are comfortable working with this higher-pressure replacement for refrigerant 22. Due to the differences between R-22 and the …R410A refrigerant cannot be reclaimed like R32, as the former is a blend. R410A operates at high pressures, which poses safety hazards. Because of these pressures, R410A requires thicker compressors and pipes to withstand the pressure, which may affect the design of your house.

R-410A refrigerant costs approximately $8 to $12 per pound or about $200 to $300 per 25-pound container. Starting in 2020, the EPA banned the import and purchase of R-22 Freon. If you have an older unit that takes R-22 refrigerant, you can’t simply add R-410A because of the pressure differences between the two products.

The temperature glide of the refrigerant R-410A and its potential direct substitutes are shown in Fig. 12, which was developed using the REFPROP database [64], keeping the condensation pressure at 20 bar, as a reference, and the evaporation pressure at 5 bar. Moreover, the average operating temperatures (equivalent to …This script determines the gas pressure based on temperature of R410a refrigerant. R410A is an HFC refrigerant, invented by Honeywell, that has been developed to replace the HCFC refrigerant R22. Systems operating on R410A run at a pressure of about 1.6 times that of similar systems operating on R22. Energy efficiency is comparable to R22.Please note that in converting enthalpy and entropy from SI to I/P units, = 0 at –40°F for I/P units). In the conversion equation below, H (ref) and S (ref) are the saturated liquid enthalpy and entropy at –40°C. For Suva® 410A, H (ref) = …Food waste and spoilage is a significant problem facing African supply chains from farm to fork. “How long is the shelf life for your fruits since you guys don’t have electricity o...Jul 5, 2019 · Digital Fieldpiece Gauges: https://amzn.to/2LFjNnKR410A Equipment: https://amzn.to/2xv6AG5My Favorite Tool: https://amzn.to/3NIFJuOTools We Recommend: https:... R-32 Refrigerant. R-410A is a perfectly good refrigerant, but there’s a new product on the market: R-32 coolant. R-32 has only one-third of the GWP than R-410A, uses 20% less refrigerant, is easier to recycle, and is more efficient. These qualities make it an even more environmentally-friendly alternative for keeping your home comfortably cool.An R-22 Replacement for New ACs and Heat Pumps. Freon™ 410A (R-410A) refrigerant offers higher cooling capacity and significantly higher pressure than R-22 for use in systems specifically designed for R-410A. This hydrofluorocarbon (HFC) refrigerant is compatible with polyolefin (POE) oils and replaces R-22 in positive displacement air ...

Heritage days in warsaw missouri.

Ixl phoenix charter.

Sep 22, 2023 · Break the vacuum on the system and supply liquid R-410A to the liquid line or receiver port. Weigh in the initial charge and ensure a proper vacuum was achieved. Adjust sensors or set points to operate the compressor continuously while charging the system. Add refrigerant to allow the discharge pressure to rise to 325-420 psig. system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3.R-410A, also known as HFC-410A, is a type of refrigerant used in commercial refrigeration and air conditioning systems. It is used in residential and commercial applications that include heating and cooling as well as dehumidification. Unlike older refrigerants like R12 or R22, R410A does not contain chlorine or bromine (which makes it non ...13 Apr 2019 ... Different refrigerant gas standing and working pressure, R32, R410A, R502, R407C, R134A, R407A, R407D, R22 Etc.R-410A REFRIGERANT 2 LBS. Now with a new shut-off valve standard ¼ ” SAE. R410A 2 lb. FREE SHIPPING NATIONWIDE (CONTINENTAL US) ... 100% VIRGIN FACTORY SEALED GUARANTEED PRODUCT QUALITY. Ability Refrigerant stocks a large store of R22, R410A, MO99, 407C, 404A and R134A. VIEW SAFETY DATA SHEET $ 129.00 …R410A refrigerant can exist in both liquid and vapor states, depending on its temperature and pressure conditions. Like most refrigerants, R410A undergoes phase changes as it circulates through the components of an HVAC (Heating, Ventilation, and Air Conditioning) system.Apr 15, 2022 · The temperature glide of the refrigerant R-410A and its potential direct substitutes are shown in Fig. 12, which was developed using the REFPROP database [64], keeping the condensation pressure at 20 bar, as a reference, and the evaporation pressure at 5 bar. Moreover, the average operating temperatures (equivalent to evaporation and ... A typical R410A refrigerant tank is pressurized to about 400 psi while the typical low side pressure of a mini split is 110-140 psi. So, if you didn’t wait for the pressure to stabilize every time you release the refrigerant into the mini split, you may end up putting too much refrigerant in the mini split. ….

What is the pressure at 100 degrees on 410A? At around 100 degrees Fahrenheit (approximately 37.8°C), the pressure for R-410A could be approximately 300 …A keypad on the outside allows you to set the temperature and also features a door lock button. Expert Advice On Improving Your Home Videos Latest View All Guides Latest View All R...On to what’s changed. Ok, so obviously the refrigerant has changed but the big and noticeable difference here is the pressure change. 410A is anywhere from fifty to sixty percent higher pressure than R-22. So, while the basic design and operating procedures of 410A remain the same as R-22 extra caution should be paid to the pressure of 410A.R410a is part of the hydrofluorocarbon (HFC) class of refrigerants and is composed of an equal amount of R125 and R32. Its chemical formula is CH₂F₂ + CHF₂CF₃ and its cylinders are colored rose. R410a was discovered by Honeywell and was granted a patent in 1991. It is the most used refrigerant in home and commercial ACs in the US, …Refrigerants - Physical Properties. 1) Production of R11 or CFC-11 was halted by the clean air act on January 1, 1996. 2) Production of R12 or CFC-12 (Dichlorodifluoromethane) was halted by the clean air act on January 1, 1996. 3) R22 or HCFC-22 is a single component HCFC refrigerant with low ozone depletion potential.For more information on Freon™ refrigerants, visit freon.com The information set forth herein is furnished free of charge and based on technical data that Chemours believes to be reliable. It is intended for use by persons having technical skill, at their ... 410A Refrigerant (R-410A) P-H Diagram (ENG Units) Enthalpy (BTU/lb) Created Date:Dari tabel tekanan freon R32, R22, dan R410a, bisa disimpulkan beberapa hal, yakni sebagai berikut. Freon R32 jauh lebih ramah lingkungan dibanding freon R410a karena tingkat GWP-nya lebih rendah dibandingkan freon R22 dan freon R410a. Freon R32 memiliki cooling index yang lebih tinggi dibandingkan dengan freon R22 dan freon …In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3. Pressure on 410a refrigerant, TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors. ADVANTAGE Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142 …, Properties of R410A Refrigerant. The R410A is a type of hydrofluorocarbon (HFC) refrigerant commonly used in AC systems, heat pumps, and commercial HVAC equipment. It was developed as an environmentally friendly alternative to older freon refrigerants like R-22. It has several benefits over traditional freon refrigerants, including a lower risk ..., The Internet of Things—a world where most working objects are online in some fashion—promises to change everyday life and boost the economy. But who knew it could make it cheaper t..., R-410A Refrigerant. R-410A is a blend of R-32 and R-125 that is 60% higher pressure than R-22 for air conditioning applications and should only be used in new equipment specifically designed to handle the pressure. Systems that are designed for R-410A will have smaller components to perform the same cooling job as R-22. R-410A will require POE ..., R410a is part of the hydrofluorocarbon (HFC) class of refrigerants and is composed of an equal amount of R125 and R32. Its chemical formula is CH₂F₂ + CHF₂CF₃ and its cylinders are colored rose. R410a was discovered by Honeywell and was granted a patent in 1991. It is the most used refrigerant in home and commercial ACs in the US, Japan ..., Dec 25, 2023 · R410A is a blend of two hydrofluorocarbon (HFC) refrigerants: R32 and R125. These two components work together to create a refrigerant with excellent thermodynamic properties. R32 provides high energy efficiency, while R125 contributes to the stability and heat transfer performance of R410A. When it comes to the chemical composition of R410A ... , TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors., Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ..., The purpose of refrigerator coils is to dissipate heat, not suck up electricity—or cash—out of your wallet. But that's what happens if you don't clean off those bad boys once in a ..., Digital Refrigerant Manifold I Use: https://amzn.to/3unWuEQYellow Jacket Gauges (More Affordable): https://amzn.to/3aghdn6My Favorite Tool: https://amzn.to/3..., Dec 25, 2023 · R410A is a blend of two hydrofluorocarbon (HFC) refrigerants: R32 and R125. These two components work together to create a refrigerant with excellent thermodynamic properties. R32 provides high energy efficiency, while R125 contributes to the stability and heat transfer performance of R410A. When it comes to the chemical composition of R410A ... , Both are HFC refrigerants. They have zero ozone depletion potential. Major differences are: R32 is a single component refrigerant while R410A is a zeotropic blend. R32 has a lower boiling point (-52.5 0 C) than R410A (-48.5 0 C) R32 has a global warming potential of 675 while R410A has a GWP of 2088. R410A will no longer be in use after …, R410a is part of the hydrofluorocarbon (HFC) class of refrigerants and is composed of an equal amount of R125 and R32. Its chemical formula is CH₂F₂ + CHF₂CF₃ and its cylinders are colored rose. R410a was discovered by Honeywell and was granted a patent in 1991. It is the most used refrigerant in home and commercial ACs in the US, Japan ..., The primary reasons for doing this are simple. One, if you recharge the refrigerant at incorrect pressure and temperature, some of your system components may fail. ... it has a lower global warming potential than R-410A. 407C has a GWP of 1774, while 410A is at 2088. The refrigerant is also safe to use if you use the proper procedure …, system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3., What is an R410A PT Chart? An R-410A Pressure-Temperature (PT) chart is a tool used in HVAC systems to determine the corresponding saturation temperature of the R-410A refrigerant at different pressures. This chart is essential for HVAC technicians as it helps in diagnosing and maintaining air conditioning systems., Some people have low blood pressure (hypotension). It is only a problem if it causes dizziness, fainting, or shock. Learn about what can cause it. You've probably heard that high b..., 410A refrigerant (ASHRAE designation: R-410A [50/50]), have been developed and are presented here. These tables are based on extensive experimental measurements. Equations have been developed, based on the Martin-Hou equation of state, which represent the data with accuracy and consistency throughout the entire range of , Have you noticed your milk getting frosty? Meat spoiling quickly? It’s likely your refrigerator is set to the wrong temperature. The FDA recommends keeping your refrigerator at or ..., Eco-Safe R-410A Refrigerant & MrCool. August 10, 2016. By MR COOL. Eco-safe R-410A refrigerant is the new standard for American air conditioners and heat pumps. As you might expect, it’s also the main refrigerant we use here at MrCool. The government, of course, required companies like us to adopt refrigerants like R-410A, but do you know why?, 410A refrigerant (ASHRAE designation: R-410A [50/50]), have been developed and are presented here. These tables are based on extensive experimental measurements. Equations have been developed, based on the Martin-Hou equation of state, which represent the data with accuracy and consistency throughout the entire range of, Genetron® AZ-20 - (R-410A) Widely accepted to replace R-22 in air conditioning and refrigeration applications. For new equipment — not for retrofits. Overview. Specifications. Resources. Save this page as PDF. Widely accepted to replace R-22 in air conditioning and refrigeration applications. For new equipment — not for retrofits., Understanding R410A Refrigerant. R410A refrigerant, also known as Puron, Forane 410A, Genetron R410A, EcoFluor R410, and Suva 410A, is a popular choice for air conditioning applications. It has a higher cooling capacity and is more energy-efficient than older refrigerants like R-22., Because R-32 efficiently conveys heat, it can reduce electricity consumption up to approximately 10% compared to that of air conditioners using refrigerant R-22. Furthermore, compared to the refrigerants widely used today such as R-22 and R-410A, R-32 has a global warming potential (GWP) that is one-third lower and is remarkable for its …, To satisfy industry regulations, the HVAC industry is transitioning from Puron (R-410A) refrigerant to Puron Advance (R-454B) by the year 2023. We talk about the implications for homeowners. Unless you work in HVAC (Heating, Ventilation, and Air Conditioning), you probably won’t need to know what R-454B refrigerant is, or why it’s a big deal., Table of Contents. Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, R410A is an HFC and is commonly used in residential and light commercial HVAC equipment for air conditioners and heat pump systems., That's correct! Refrigerant 410a, also known as R-410a, is a hydrofluorocarbon (HFC) refrigerant commonly used as a replacement for R-22 in residential and light commercial air conditioning and heat pump systems. It has become the leading choice for such systems due to its high cooling capacity and significantly higher pressure compared to R-22., This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron., The R410a systems also use synthetic oil for lubrication instead of mineral oil as in R22 systems. The synthetic oil is more soluble and more effective for the whole system. Therefore, R410a performs better than R22 and has improved machine performance. R410a Vs. …, November 2, 2003. Several major manufacturers are producing comfort air conditioning equipment using refrigerant 410A. The trend towards the use of R-410A continues to grow and there is a demand for technicians who are comfortable working with this higher-pressure replacement for refrigerant 22. Due to the differences between R-22 and the newer ..., The higher the GWP the more harm the refrigerant does to the climate. R-410A has a GWP of over two-thousand whereas R-32 has a GWP of only six-hundred and seventy-five. While R-32 isn’t perfect it is a lot better then R-410A. That is why we are beginning to see a rise of usage of R-32 in the European Union and here in the United …, R-410A PRESSURE TEMPERATURE CHART. PSIG. 12. 14. 16. 18. 20. 22. 24. 26. 28. 30. 32. 34. 36. 38. 40. 42. 44. 46. 48. 50. 52. 54. 56. 58. 60. 62. 64. 66. 68. 70. 72. 74. 76. …, Oct 31, 2023 · The weight of an empty R-410A refrigerant cylinder can vary, but it is typically around 20 to 25 pounds (9 to 11.3 kilograms). What refrigerant is replacing R410A? Several low-GWP refrigerants, such as R-32, R-454B, and R-452B, are being considered as replacements for R-410A in various regions.