Suction pressure for 410a

For air conditioning system, R22 pressure in discharge is250psi and suction in67psi. But for R410A pressure will be more higher that R22. So what pressure is normal for air-conditioning systems. Besides that normal R22 compressor can replace with R410A. by Mohammed Awais haji Latif.

Suction pressure for 410a. R410A PRESSURE-TEMPERATURE CHART Saturation Pressure-Temperature Data for R410A (psig)* ECLPC-1 Rev 1 – 02/22. Created Date: 2/25/2022 1:24:53 PM ...

I have high suction pressure and slightly low to correct head pressure. It is a heat pump operating in heat mode. Filters are clean and indoor coil is clean as well. ... R410a Copeland scroll (single speed with bypass for two stages cooling). Running on high, Suction 140 psig, liquid 300 psig, superheat 9F, ...

psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114View and Download Rheem R-410A installation instructions manual online. PRL-JEC Series two-stage heat pump outdoor units. R-410A heat pump pdf manual download. Also for: Prl-jec series, 024jec, 036jec, 048jec, 060jec. ... Low Suction Pressure Moisture freezing and blocking valve Recover charge, install filter-drier, evacuate system, ...R-410A Pressure-temperature chart Click anywhere on this document to return to Refrigerant Gas Properties information at InspectApedia.com This chart was provided by the Bonneville Power Authority,Jul 21, 2009 · R-410A refrigiant. The Suction pressure temperature chart in the Condensing Unit installation & service reference that came with the unit only goes up to 80 psig, yet I'm seeing 135 psig at the low side service valve. Looking elwhere I found that 135 psig is 47F. High side 285 psig which is 92F. Spec is SH 7-9F and SC 7-9F (using TXV). SC: 92F ... what would cause the high side and low side pressure on a r410a 3 ton goodman heat pump to be 400+ psi? The unit was charged in heating mode and 11lbs 1 oz of refrigerant was used. ... high suction pressure 130 plus low discharge pressure 150. No heat outside coil freezes maybe a bad compressor.Continue the process until the system has been determined to be leak-free. Connect the vapor-line and liquid-line pressure taps to a vacuum pump and micron meter. This step is also almost always omitted. Evacuate the refrigerant lines and indoor coil to at least 350 microns. Close off the valve to the vacuum pump and observe the micron meter.Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold. The TXV is backed all the way …In this HVAC Training Video, I Show If You Can Check The Refrigerant Charge on an Inverter Mini-Split Ductless Unit on a Service Call by measuring superheat ...

Constants for vapor pressure of saturated vapor (dew point), p g: A = –1.440004 E+00 E = –3.521484 E+00 B = –6.865265 E+00 F = –7.750000 E+00 C = –5.354309 E–01 X o = 2.086902 E–01 D = –3.749023 E+00 Because both pressure and temperature appear in the reduced form in the equation, the same constants can be used for either SI or ...Discharge line temperature 150°F (65°C) or higher at the end of the freeze cycle. Discharge line temperature less than 150°F (65°C) at the end of the freeze cycle or Compressor shell is frosted. Evaporator Outlet Temperature Comparison. Attach and insulate temperature probes between evaporator outlet and 90° elbow.ESIEN05-04 Disassembly and Maintenance 1.11.1 Removal of Suction Grille Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Procedure: Step Procedure Points 1 Removing the suction grille Push the buttons and pull down Push the 2 buttons When closing, push up the simultaneously and pul... The higher pressure, and the fact that R-410A performs very much like a single component refrigerant, provide an opportunity to produce a more compact system with greater efficiency. In addition, R-410A refrigerant allows more suction line pressure drop since it is less sensitive to suction line efficiency losses. The higher pressure, and the fact that R-410A performs very much like a single component refrigerant, provide an opportunity to produce a more compact system with greater efficiency. In addition, R-410A refrigerant allows more suction line pressure drop since it is less sensitive to suction line efficiency losses.

My very wild guess would be an obstruction somewhere in the coil or suction line. You eliminated every other cause for a high low pressure (Air flow, refrigerant, compressor txv). I would try touching and observing the piping for any sudden change in temperature. Student here, so take this with a grain of salt. 2. 1. Even though this is not the cause of high suction, Clean The Evaporator, because it needs to be clean. If it's dirty, it causes LOW suction pressure, and causes inexperienced techs to overcharge a system. 2. Just for kicks, and for a learning experience, check the system vitals, and record the pressures, water temp entering and leaving the ...Physics GCSE AQA Electricity. 58 terms. xero33. Preview. Study with Quizlet and memorize flashcards containing terms like T/F: R-22 and R-410A operate in the same range of condensing and evaporating temperatures., T/F: R-410A can segregate in the system or chemically change its composition due to a leak., T/F: R-410A is a drop in replacement ...The liquid line pressure at 108°F saturation temperature is 356.5 PSIG. This screenshot of the Ref Tools app shows the liquid line pressure of R410A at saturation at 108°F. Notice how the slider has been set to BUBBLE point (inside the orange box). Vapor Line Pressure: Again, we already have the return air temp data, which is 74°F.The internal pressure relief valve is located between the high and low side of the compressor. It is designed to open when the discharge-to-suction pressure differential exceeds 550 to 625 psid (38-43 bar). When the valve opens, hot discharge gas is routed back into the area of the motor protector to cause a trip.“For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 …

Dr steven greer press release.

Suction pressure R410A. I ran a system today and had a suction pressure of 5 bar. I have never seen one so low on 410A and charged to manufacturers guidelines, there was frosting on suction valve and inlet/outlets to evap after a couple of minutes. Acson A5LC25CR-ACPOC-R outdoor unit connected to AHU.™ 410A Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics of Freon™410A Refrigerant in Very Low Temperature Systems ... Suction Pressure, kPa (psia) 104 (15) 138 (20) Discharge Pressure 1484 (215) 1470 (213) Discharge Temperature 128 (263) 92 (197)This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.Many servicemen experience service calls where the compressor has both a low head pressure and a high suction pressure. Often, the refrigeration equipment is still running, but the product temperature is suffering about 7 to 10°F. These calls are tough to handle because the compressor is still cooling, but not cooling to its rated capacity.If pressure drop exceeds 3 psig, replace suction-line and liquid-line filter driers. Be sure to purge system with dry nitrogen and evacuate when replacing filter driers. Continue to …The R410A PT chart can be used to answer questions like: What are normal operating pressures for 410A? What is the pressure of r410a at 72 degrees Fahrenheit? What should gauge read for 410A? You can also use the R-410A PT chart to adequately calculate the superheat, total superheat, and subcooling temperatures.

1. Even though this is not the cause of high suction, Clean The Evaporator, because it needs to be clean. If it's dirty, it causes LOW suction pressure, and causes inexperienced techs to overcharge a system. 2. Just for kicks, and for a learning experience, check the system vitals, and record the pressures, water temp entering and leaving the ...Suction pressure control — loss of charge P170AA-400C SPST Open Low 100 470 690 Fan cycling for head P170CA-400C SPST Open High 200 610 690 ... PRESSURE CONTROLS COMPATIBLE WITH R-410A COMMERCIAL REFRIGERATION CONTROLS * Maritime models for use with corrosive media. ** Low-flow model.Quick Example: Let’s say that we have a 3-ton 16 SEER AC are using R-410A refrigerant and want to calculate R-410A superheat. With low side blue gauge on the suction line service port, we measured 130 psi pressure that correlates (according to R-410A PT chart) to about 45°F. The clamp-on thermometer shows that the saturated refrigerant ...R32, R410 gas pressure for 1.5 ton inverter ac is 120–130 psi. For R22 gas pressure should be 60–70 psi. What is suction and discharge pressure of R-410A? With R-410A, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi, as shown in Figure 1 on the next page.With 410a heat pumps is there a recommended suction pressure. For example with R22 air-con systems I always aim for 400 suction and 1500 discharge and similar with 407c systems. I have been told to aim for round the 100 psi/700kpa mark with is about 0 degree C Was just curious for fault finding purposes. Cheers in advance, chris. psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114 psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114 Many servicemen experience service calls where the compressor has both a low head pressure and a high suction pressure. Often, the refrigeration equipment is still running, but the product temperature is suffering about 7 to 10°F. These calls are tough to handle because the compressor is still cooling, but not cooling to its rated capacity.An R-410A Pressure-Temperature (PT) chart is a tool used in HVAC systems to determine the corresponding saturation temperature of the R-410A refrigerant at different pressures. This chart is essential for HVAC technicians as it helps in diagnosing and maintaining air conditioning systems.The pressures were still at the 130 on suction side and 335 on the high side, but the cooling has gone away, suction side does not get cool. It has a metering orifice, no txv So, I thought I may be overcharged, since the liquid got in. I reclaimed some 410a (not measured) which sent the pressure too 150 on suction side and 365 on high side ...

the heat content of the return air (including the sensible temperature) drops, the saturated suction temperature will drop, resulting in a drop in suction pressure. As the suction pressure falls to 120psig the APR Control will begin to open and attempt to stabilize the system suction pressure at approximately 120psig.

Our Ebook, Paperback, Workbook, Quick Cards: https://www.acservicetech.com/the-book This video is on Normal Operating Pressures are for Freon R-22 and R-410A...Both older R-22 and R-134 operate at lower pressures than R-410A. R22 Refrigerant Pressure Rules of Thumb Typical Off, Low, High side R22 Pressures & Temperatures. On a properly-charged and working air conditioning system using R-22 refrigerant. Low pressure refrigerant switches on Carrier HVACR typically open at 50 psi and close at 100 psi.When the refrigerant is flowing in the suction line from the compressor to evaporator coil without any leakage or damaging the compressor’s piston and also there no impurities are present then the pressure range will be inside the system is 0.75 – 1.3 MP ,this called the High suction pressure normal head pressure.This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.R-410A and R-22 is the higher operating pressures (approximately 50% higher on both the discharge side and the suction side).For example, a high-efficiency condensing unit using R-22 typically operates with a suction pressure of about 68 psi and a discharge pressure of about 250 psi at an outdoor temperature of 95°F.The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.Typical low pressure or suction side, may vary by equipment and metering controls - these are "gauge pressure readings" or "psig" ... Both older R-22 and R-134 operate at lower pressures than R-410A. R22 Refrigerant Pressure Rules of Thumb Typical Off, Low, High side R22 Pressures & Temperatures.

Case 1840 specs.

Oreillys snyder tx.

The liquid line pressure at 108°F saturation temperature is 356.5 PSIG. This screenshot of the Ref Tools app shows the liquid line pressure of R410A at saturation at 108°F. Notice how the slider has been set to BUBBLE point (inside the orange box). Vapor Line Pressure: Again, we already have the return air temp data, which is 74°F.Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation.Nov 2, 2003 · November 2, 2003. Several major manufacturers are producing comfort air conditioning equipment using refrigerant 410A. The trend towards the use of R-410A continues to grow and there is a demand for technicians who are comfortable working with this higher-pressure replacement for refrigerant 22. Due to the differences between R-22 and the newer ... Our Ebook, Paperback, Workbook, Quick Cards: https://www.acservicetech.com/the-book This video is on Normal Operating Pressures are for Freon R-22 and R-410A...Suction pressure R410A. I ran a system today and had a suction pressure of 5 bar. I have never seen one so low on 410A and charged to manufacturers guidelines, there was frosting on suction valve and inlet/outlets to evap after a couple of minutes. Acson A5LC25CR-ACPOC-R outdoor unit connected to AHU.By contacting an HVAC technician, you can get your AC system’s suction pressure back to normal levels. If you are experiencing a problem with your air conditioning or heating call us at 512-336-1431 to schedule an appointment. We’ll be glad to come out and take a look at the issue. 1431-183 A/C & Heating proudly serves Round Rock ...TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors. ADVANTAGE Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142 … Mini Split R410a Low Side Suction Charging Service Gauge Hose Set 5/16" Port. 91 Reviews. SKU: PGML-5/16B1/4Y. Free Shipping for Orders Above $49. Wholesale Price Directly From Factory. Secure and Versatile Payment Options. In stock, ready to ship. Price $35 52 $29 99 Save $5.53. Buy in monthly payments with Affirm on orders over $50. ….

Refrigerant Type R-410A R-410A R-410A R-410A R-410A R-410A R-410A Refrigerant Charge (limit) lbs 13 13 13 17 17 17 17 Oil Type Trane OIL00079 (qt)/OIL00080 (gal) Oil Charge oz 101 101 101 88 112 112 112 Suction Fitting Connection Brazed Brazed Brazed Brazed Brazed Brazed Brazed Suction Fitting (ODF) in 1.125 1.125 1.125 1.375 1.375 1.375 1.375 I have a 3 ton 410a Lennox with correct suction pressure however my high side pressure is way low. Pressures are 120headover 118 suction low side. What would be the cause. Bad txv or tev. On 2018-05-26 by (mod) - I might look for a thermostatic expansion valve that is not closing when it should or is not correctly adjusted.In this HVAC Training Video, I show the Step By Step Procedure for Charging R-410A Refrigerant into an Air Conditioner that is Low on Refrigerant. I show the...Jun 24, 2020 · We will first examine the low-pressure side of the system, otherwise known as the vapor or suction line. During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. Typical low pressure or suction side, may vary by equipment and metering controls - these are "gauge pressure readings" or "psig" ... Both older R-22 and R-134 operate at lower pressures than R-410A. R22 Refrigerant Pressure Rules of Thumb Typical Off, Low, High side R22 Pressures & Temperatures.• Protected compressor - Compressors are protected internally by a high pressure relief valve and a temperature sensor, and externally by the system high and low pressure …On a properly functioning R-22 system running in heat mode in 40-degree weather, the suction pressure tends to be around 40 PSIG. This guideline obviously doesn't work on an R-410A system or any other refrigerant. A more applicable guideline is 20-25˚ suction saturation below outdoor ambient temperature.Find out what causes high suction pressures and the consequences of high suction pressure. We examine the refrigeration cycle and work to solve the root of high suction pressure 410a problems. Read more with HVAC Brain. ... 1.5 - 3 TON TXV R410A) Table 1: R134a Saturation Properties pressure table (Reference: …Operating an air conditioner for extended periods of time in low temperatures outdoors lowers the suction pressure to a velocity where the oil will not return to the compressor and will run dry. Also, under low ambient conditions “indoors” does not provide sufficient load to change refrigerant from a liquid to a 100% vapor. Suction pressure for 410a, Saturation Pressure-Temperature Data for R410A (psig)*., Jun 7, 2021 · r410a high/low pressures. Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold. , About this video in Learn Refrigerant 410A Gas complete information new technician must watch this video open this link https://youtu.be/O8TbwOxlo8kYou want ..., If you’re planning to spruce up your outdoor areas or you're planning to start a pressure washing business, investing in a high-quality pressure washer Expert Advice On Improving Y..., This Guide covers R-22, R-407C, R-410A, and R-134a used in commercial air conditioning systems. It does not apply to industrial refrigeration and/or Variable RefrigerantVolume ... Temperature versus Pressure Drop Refrigerant Suction Pressure Drop Discharge Pressure Drop Liquid Pressure Drop °F (°C) PSI (kPa) °F (°C) PSI (kPa °F (°C) PSI ..., Study with Quizlet and memorize flashcards containing terms like Because of its higher vapor heat capacity, the discharge temperature of R-410A is _____ than R22, Both suction and discharge pressures of R-410A systems are _____ than R-22 systems, The temperature glide for R-410A is less than _____ degrees Fahrenheit over air conditioning and refrigerating operating ranges and more., On a properly functioning R-22 system running in heat mode in 40-degree weather, the suction pressure tends to be around 40 PSIG. This guideline obviously doesn't work on an R-410A system or any other refrigerant. A more applicable guideline is 20-25˚ suction saturation below outdoor ambient temperature., A R-410A evaporator running below 100 psig will freeze-up just like its R-22 cousin. One of the most common causes of low suction pressure is loss of critical refrigerant charge caused by small leaks over time. Explore heat pumps, heat pump reviews, costs, brands, manufacturers, knowledge, questions, visit heatpumpmeta.com., Suction pressure R410A. I ran a system today and had a suction pressure of 5 bar. I have never seen one so low on 410A and charged to manufacturers guidelines, there was frosting on suction valve and inlet/outlets to evap after a couple of minutes. Acson A5LC25CR-ACPOC-R outdoor unit connected to AHU. , When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. Last updated: 19 days ago – 12 co-authors – 9 users., The image above is of the Danfoss refrigerant slider app, and it shows that when suction pressure drops below 102 PSIG on an R410a system, the coil hits 32° and will start to freeze. ... Let's say it's 78° in a house on an R410a system, and your suction pressure is 108 PSIG (as shown). Your suction saturation (coil temperature) is 35°. So ..., the heat content of the return air (including the sensible temperature) drops, the saturated suction temperature will drop, resulting in a drop in suction pressure. As the suction pressure falls to 120psig the APR Control will begin to open and attempt to stabilize the system suction pressure at approximately 120psig., Anon The compressor is running and producing no pressure it's possible that it's because you've lost the refrigerant charge from the system. On 2020-06-14 - by (mod) - Possibly a jammed TEV. On 2020-06-13 by Clay what causes high pressure on the suction line on Rheem R410a ? On 2020-06-11 by Anonymous, A R-410A evaporator running below 100 psig will freeze-up just like its R-22 cousin. One of the most common causes of low suction pressure is loss of critical refrigerant charge caused by small leaks over time. Explore heat pumps, heat pump reviews, costs, brands, manufacturers, knowledge, questions, visit heatpumpmeta.com., R-410A refrigiant. The Suction pressure temperature chart in the Condensing Unit installation & service reference that came with the unit only goes up to 80 psig, yet I'm seeing 135 psig at the low side service valve. Looking elwhere I found that 135 psig is 47F. High side 285 psig which is 92F. Spec is SH 7-9F and SC 7-9F (using TXV). SC: 92F ..., On a properly functioning R-22 system running in heat mode in 40-degree weather, the suction pressure tends to be around 40 PSIG. This guideline obviously doesn't work on an R-410A system or any other refrigerant. A more applicable guideline is 20-25˚ suction saturation below outdoor ambient temperature., Low-side air conditioner compressor motor pressure: This is the pressure in the air conditioner's refrigerant suction line (low side pressure during compressor operation) and this will be a relatively low number, often less than 100 psi. During operation, refrigerant is returning to the compressor from the cooling (evaporator) coil in this line., Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both sides, begin from 365 on suction and liquid lines and …, work on 2 years old r410a heat pump,run in heat mode vapor line pressure 335 psig vapor line temp 80F,liquid line pressure 280psig,ture suction 98 psig,feel like the indoor txv check valve not open enough,switch out new txv,pressure both vapor and liquid only 2 psig different,and vapor line temp go up to 150F,pack u my stuff went home,5 …, Pressure stockings will improve blood flow in the veins of your legs and lower your risk for blood clots and their complications. The stockings use graduated pressure to keep blood..., Nov 11, 2022 · 2. Record the temperature and measure the suction pressure at the suction lines. 3. Convert the suction pressure recorded to the temperature using the temperature/ pressure Chart. 4. To calculate superheat simply subtract the two temperature values. IMPORANT: In most systems. 1. Superheat is about 10 degrees when measured at the evaporator and. 2. , R410A Pressure Temperature Chart (In Fahrenheit) Printable PDF Temp er atu r e (° F ): R410A P r essu r e (p si g ):-60 ° F 0. 9 psi g-55 ° F 1. 8 psi g-50 ° F 4. 3 psi g-45 ° F 7. 0 psi g-40 ° F 10. 1 psi g-35 ° F 13. 5 psi g-30 ° F 17. 2 psi g-25 ° F 21. 4 psi g-20 ° F 25. 9 psi g-18 ° F 27. 8 psi g, Study with Quizlet and memorize flashcards containing terms like Because of its higher vapor heat capacity, the discharge temperature of R-410A is _____ than R22, Both suction and discharge pressures of R-410A systems are _____ than R-22 systems, The temperature glide for R-410A is less than _____ degrees Fahrenheit over air conditioning and refrigerating operating ranges and more. , Mar 8, 2010 · Many servicemen experience service calls where the compressor has both a low head pressure and a high suction pressure. Often, the refrigeration equipment is still running, but the product temperature is suffering about 7 to 10°F. These calls are tough to handle because the compressor is still cooling, but not cooling to its rated capacity. , R-410A and R-22 is the higher operating pressures (approximately 50% higher on both the discharge side and the suction side).For example, a high-efficiency condensing unit using R-22 typically operates with a suction pressure of about 68 psi and a discharge pressure of about 250 psi at an outdoor temperature of 95°F., Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae of the components that make up Freon™ 407C and Freon™ 410A. Table 1. Components of Freon™ 407C: HFC-32/HFC-125/HFC-134a and Freon™ 410A: HFC-32/HFC-125, Trying to diagnose a 2 year old Amana heat pump with high suction and discharge pressures in heat mode. ASZ 16 SEER OD unit matched up with an ARUF Goodman piston air handler. Both are 2 ton 410A units. 10kw heat kit and lineset is about 20ft long. HEAT MODE Unit is tripping out on high head(600psi). Upon starting, the unit …, Theoretical calculations reveal that at the above high-temperature cooling conditions, a 2-psi suction pressure drop produces about 2% loss of efficiency and 2.4% loss of capacity in an R-22 system. But in an R-410A system, the suction pressure drop can be allowed to go as high as 3.1 psi before the same losses in performance are seen., If the suction pressure is 45 psi, (which converts to 22 ° F) and the suction temp is 32 ° F, the system still has 10 ° F of superheat. The fact that these readings are normal indicates the low suction pressure is not caused by low refrigerant, but insufficient heat getting to the evaporator. CAUSE #2: Defective, plugged, or undersized ..., The fuel-injection system in a Toyota truck requires a specific fuel pressure at all times or else the engine will not run correctly. If your Toyota's idle is dropping or you think..., In this HVAC Refrigerant Charging Video I go over what it means to have low R22 Freon or Low R410A Suction Vapor Pressure along with a Low Superheat. I expla..., Newly released blood pressure suggestions recommend lifestyle changes as a first step toward achieving healthy levels. Trusted Health Information from the National Institutes of He..., HVAC Technician: Mark Henley. Hi, Even with a different refrigerant you are still looking for the same coil temperature. So if you want a 40 degree indoor coil you will be at 120 PSI on the low side, then say you want a 100 degree condensing temperature ( 80 degree day ) you are looking for 320. The desired high side target pressure will change ...