Em385

EM385 and USACE Compliant Competent Person Training. Ellis Fall Safety Solutions is the premier destination for Army Corps of Engineers Fall Protection training courses, specifically EM 385-1-1 training. With over 50 years of experience in Working at Heights and Fall Safety training and regulations, our tailored three-day (24-hour) EM 385 ...

Em385. Temporary, destroy when no longer needed. This material is an informational copy. See proponent for official copy. CONTENTdm number. 54. CONTENTdm file name. 55.cpd.

EM 385-1-1 XX Jul 14 14-4 e. All hoist way entrances shall be protected by substantial gates or bars that shall guard the full width of the landing entrance. Gates shall be not less than 66 in (167.6 cm) in height, with a maximum under clearance of 2 in (5 cm), and shall be located not more than 4 in (10 cm) from the hoist way line.

EM 385-1-1 (July 2014) 01.A.14 Contractor Risk Management Process (AHAs) b. Before beginning each work activity, task or (DFOW), the Contractor performing that work activity shall prepare the initial AHA. A Risk Assessment Code (RAC) is assigned to each step, to the risk that remains after controls have been applied (residual risk). www.publications.usace.army.mil What our 40-Hour EM 385-1-1 Online course offers. This course consists of 34 modules that must be completed at a minimum of 40 hours. Each module has a 5-8 question quiz, which must be passed with a 70% or higher. However, students are allowed to take the quiz an unlimited number of times. The course also includes a 25-question final exam. www.publications.usace.army.milmust be familiar with the requirements of EM 385-1-1 and have experience in the areas of hazard identification and safety compliance. The individual must be capable of interpreting a critical path schedule and construction drawings. The qualification requirements for the alternate superintendent are the same as for the project superintendent. The EM 385-1-1 30 Nov 14 1-3 b. The current Unified Facilities Guide Specification (UFGS) for Safety and Health in effect on the date of solicitation shall be used in all USACE contract work administered on behalf of the USACE under the provisions of FAR Clause 52.236-13 EM 385-1-1 XX Jul 14 1-2 01.A.07 SOH Bulletin Board. The Contractor or USACE Project shall erect and maintain a SOH bulletin board in a commonly accessed area in clear view of the on-site workers. The bulletin board shall be continually maintained and updated and placed in a location that is protected against the elements and unauthorized removal.

This EM 385 training course is based off of, and complies with, the US Army Corps of Engineers EM 385-1-1 manual, and is compliant with the most recent 2014 revisions to that manual. This training, and the EM 385-1-1 manual, prescribes the safety and health requirements for all Corps of Engineers activities and operations. This.EM 385-1-1 8 hour Safety Training i . Online Training $170. DIY Kits . Train The Trainer . DIY Kits . Product Details . EM 385-1-1 16 hour Safety Training i . Online Training $195. DIY Kits . DIY Kits . Train The Trainer . Product Details . Emergency Response Safety Training i . Online Training .EM 385-1-1 30 Nov 14 1-3 b. The current Unified Facilities Guide Specification (UFGS) for Safety and Health in effect on the date of solicitation shall be used in all USACE contract work administered on behalf of the USACE under the provisions of FAR Clause 52.236-13 .EM 385-1-1 30 Nov 14. 24-12 b. Carabiners and snap hooks: Used for climbing (life support) shall have at least two consecutive, deliberate actions to prepare the gate for opening and shall be rated at 5,000 lbs (22.2kN) and shall meet the ANSI/ASSE Z359 Fall Protection Code. Gates shall be rated at 3600 lbs (16kN).EM 385-1-1 XX Jul 14 16-2 g. Machinery that hoists by using a come-a-long or chainfall (whether human-, air- or electric- powered, chain or wire-rope type); h. Operators of equipment with a maximum manufacturer-rated hoisting/lifting capacity of 2,000 pounds (907 kg) or less, are exempt from the operator qualification or

EM 385-1-1 30 Nov 14 22-4 22.B.06 Anyone involved in erecting, disassembling, moving, operating, using, repairing, maintaining or inspecting a scaffold shall be trained by a CP to recognize any hazards associated with the work in question. Proof of training shall be maintained on site and made available to the GDA upon request. EM 385-1-1 30 Nov 14 1-3 b. The current Unified Facilities Guide Specification (UFGS) for Safety and Health in effect on the date of solicitation shall be used in all USACE contract work administered on behalf of the USACE under the provisions of FAR Clause 52.236-13 EM 385-1-1 30 Nov 14 16-2 h. Operators of equipment with a maximum manufacturer -rated hoisting/lifting capacity of 2,000 pounds (907 kg) or less, are exempt from the operator qualification or certification requirements in Sections 16.B.02 through 16.B.05 only. In addition, this equipment may not be used to hoist personnel ; i. provide policy, programs, technical services, oversight and outreach related to safety and occupational health matters in support of USACE missions worldwide. May 1, 2011 · Environmental Quality: Minimizing the Risk of Legionellosis Associated with Building Water Systems on Army Installations. 9/30/2016. EM 200-1-15. CEMP-CE. Environmental Quality Technical Guidance For Military Munitons Response Actions. 10/30/2018. EM 200-1-16.

Www.theworknumber.com.

DEPARTMENT OF THE ARMY EM 385-1-1 U.S. Army Corps of Engineers CESO-ZA Washington, D.C. 20314-1000 For sale by the U.S. Government Printing Office Superintendent of Documents, Mail Stop: SSOP, Washington, DC 20402-9328 ISBN 0-16-048877-x Manual No. 385-1-1 3 November 2003 Safety SAFETY AND HEALTH REQUIREMENTS 1. Washington, DC 20314-1000. ER 385-1-40. 20 September 2010. Safety. OCCUPATIONAL HEALTH PROGRAM. Purpose. This regulation prescribes policies, outlines responsibilities, and provides procedures for the development and execution of the U.S. Army Corps of Engineers (USACE) Occupational Health (OH) Program. standardization of all safety programs. The EM 385–1–1 prescribes the safety and health requirements for all Corps of Engineers activities and operations. The USACE is soliciting comments on the proposed revisions to EM 385–1–1. USACE intends to update the manual and periodically thereafter, to reflect such public input, experience,EM 385-1-1 30 Nov 14 23-5 g. Where material is dumped from mechanical equipment or wheelbarrows, a toe board or bumper, not less than 4 in (10 cm) thick and 6 in (15 cm) high, shall be attached at each chute opening. h. Chutes shall be designed and constructed of such strength as to eliminate failure due to impact of materials or debris loaded ...

EM 385-1-1. f. AR 690-700, Chapter 751. 1-5. Policy. It is the policy of the USACE to: a. Protect all persons that are directly involved with or affected by the installation, servicing and/or maintenance of machines and equipment. b. Require a current, written Activity Hazard Analysis for the work to be ...standardization of all safety programs. The EM 385–1–1 prescribes the safety and health requirements for all Corps of Engineers activities and operations. The USACE is soliciting comments on the proposed revisions to EM 385–1–1. USACE intends to update the manual and periodically thereafter, to reflect such public input, experience,EM 385-1-1 30 Nov 14 29-2 29.A.03 All persons working with explosives shall be in good physical condition and be able to understand and give written and verbal orders. 29.A.04 Warning signs shall be provided at points of access to blasting area. Books. Em 385-1-1: Safety and Health Requirements Manual. The manual describes safety and health requirements for all Corps of Engineers activities and operations, including Naval Facilities Engineering Command (NAVFAC) construction contracts. Following this manual will help all contractors working on DoD projects to meet all of the necessary ... EM 385-1-1 30 Nov 14 3-5 d. First aid kits shall be easily accessible to all workers and protected from the weather. The individual contents of the first aid kits shall be kept sterile. First aid kit locations shall be clearly marked and distributed throughout the site(s).The United States of America, Department of the Army, U.S. Army Corps of Engineers, Engineering Manual 385-1-1 is exactly that, a manual developed, printed and administered by the USACE. Presently, it is titled as US Army Corps of Engineers, EM 385-1-1, Safety and Health Requirements Manual. The Preface of the EM 385-1-1 merits close …05.C.01. The employer must evaluate the workplace for noise hazards initially and regularly during the course of work. Protect your ears from excessive noise. When noise hazards are known or expected, the employer must develop a Hearing Conservation Program that includes identification and assessment of noise hazards and the measures to be ...REQUIRED BY EM 385-1-1 2014 Contract Name and Number: [ProjectName] [ProjectNumber] Contractor/Subcontractor: [CompanyName] Government Inspector: Location: Contractor Inspector: Date: NOTE: The following plans should be on site and accessible to employees. The expected answer should be yes to all applicable plans. in conjunction with ER 385-1-80 and EM 385-1-1. Contractor requirements concerning ionizing and non-ionizing radiation protection issues are contained in EM 385-1-1. 1-3. Distribution Statement. Approved for public release; distribution is unlimited. 1-4. References. Appendix A contains a list of references used in this manual. 1-5. Policy. a. This EM 385 training course is based off of, and complies with, the US Army Corps of Engineers EM 385-1-1 manual, and is compliant with the most recent 2014 revisions to that manual. This training, and the EM 385-1-1 manual, prescribes the safety and health requirements for all Corps of Engineers activities and operations. This.

EM 385-1-1 (July 2014) 01.A.14 Contractor Risk Management Process (AHAs) b. Before beginning each work activity, task or (DFOW), the Contractor performing that work activity shall prepare the initial AHA. A Risk Assessment Code (RAC) is assigned to each step, to the risk that remains after controls have been applied (residual risk).

EM 385-1-1: CESO: Safety and Occupational Health (SOH) Requirements: 3/15/2024: EM 200-1-12: CEMP-CE: Environmental Quality: Conceptual Site Models: 8/11/2023: EM 5-1-11: CECW/CEMP: Project... CICB’s four-day program for US Army Corps of Engineers (USACE) EM 385-1-1 Training has been developed with the objectives to assist USACE personnel, contractors or management and employers achieve and maintain compliance with this comprehensive standard. This manual applies to Headquarters, US Army Corps of Engineers elements, … EM 385-1-1 30 Nov 14 9-3 09.A.11 Measures must be taken to control the growth of tall grass, brush, and weeds adjacent to facilities. A break of at least 3 ft (0.9 m) shall be maintained around all facilities. 09.A.12 Paint-soiled clothing and drop cloths, when not in use, shall be stored in well-ventilated steel cabinets or containers. 09.A. standardization of all safety programs. The EM 385–1–1 prescribes the safety and health requirements for all Corps of Engineers activities and operations. The USACE is soliciting comments on the proposed revisions to EM 385–1–1. USACE intends to update the manual and periodically thereafter, to reflect such public input, experience,May 1, 2011 · Environmental Quality: Minimizing the Risk of Legionellosis Associated with Building Water Systems on Army Installations. 9/30/2016. EM 200-1-15. CEMP-CE. Environmental Quality Technical Guidance For Military Munitons Response Actions. 10/30/2018. EM 200-1-16. www.publications.usace.army.mil EM 385-1-1 forms and informational material for reference and review. USACE EM 385-1-1 2014 PDF, USACE Coy Fax Form, EM 385-1-1 book purchase, etc.EM-385 is the code for the safety and health requirements written and constantly updated by the US Corps of Engineers and is meant to regulate DoD projects. This manual very much resembles OSHA, which should not come as a surprise, since both codes are meant to promote occupational health and safety. For instance, both OSHA and EM-385 require ...

Flights from nyc to tokyo japan.

Okcs.

This training fulfills the SSHO requirement to maintain his/her competency according to EM-385-1-1 Section 01.A.17d. This course includes the following objectives: - Discuss all recent revision changes of EM 385 1-1, 2014 - Explain why changes are required and how their application applies towards developing safe and healthful construction processes. CICB Senior Instructor Larry Kime introduces us to EM385-1-1. Larry reminds us that contractors on a military installation must be aware of more than the OSHA regulations and ANSI/ASME standards. US Army Corps of Engineers (USACE) EM385-1-1 is a broad range safety standard written into any contract for contractors on a military installation. The United States of America, Department of the Army, U.S. Army Corps of Engineers, Engineering Manual 385-1-1 is exactly that, a manual developed, printed and administered by the USACE. Presently, it is titled as US Army Corps of Engineers, EM 385-1-1, Safety and Health Requirements Manual. The Preface of the EM 385-1-1 merits close …EM 385-1-1 XX Jul 14 22-7 (2) Where the employer makes the demonstration as described in 22.B.08(d)(1), the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 ½ in (24.1 cm). e. When planking is lapped in a long run, each plank shall lap its supports at ...Course content complies with the requirements within OSHA 1926.32(f), 1926.500, 1910 ANSI/ASSE Z359.2 code. (EM 385-1-1, updated March 2015) (24-hours) standards. Additionally, this course will prepare the participant with the knowledge and skills to perform the annual inspection and record-keeping under these standards.A Prefeitura do Rio anunciou, nesta segunda-feira (22/4), um total de 1.316 novas vagas de emprego para trabalhadores, com e sem deficiência. São 931 vagas para trabalhadores em geral, e outras 385 destinadas a pessoas com deficiência. O destaque fica por conta dos frentistas, profissionais que trabalham nos postos de combustíveis: …EM 385-1-1 XX Jul 14 33-2 c. Hazardous waste operations performed by Government personnel do not require development of an APP, but do require a Project Safety and Health Plan and a SSHP in compliance with Section 01.A.09 and local safety and health policies for in-house activities. All activities shall comply with the written SSHP.EM 385-1-1 (2024 Edition) 12-Hour Refresher Online. We offer a 40-Hour (2014 Edition) and 12-Hour Refresher (2024 Edition) course for EM 385-1-1 required for US Army Corps of Engineers Safety and Health Requirements which upon the completion of this course, you will receive an EM 385-1-1 certificate that is valid for 5 years. provide policy, programs, technical services, oversight and outreach related to safety and occupational health matters in support of USACE missions worldwide. EM 385-1-1 30 Nov 14 5-4 05.B.05 Operations that require handling of harmful materials (e.g., acids, caustics, hot liquids, or creosoted materials) and operations where protection from gases, fumes, and liquids is necessary, shall require the wearing of goggles with cups of soft pliable rubber ….

EM 385-1-1 30 Nov 14 5-4 05.B.05 Operations that require handling of harmful materials (e.g., acids, caustics, hot liquids, or creosoted materials) and operations where protection from gases, fumes, and liquids is necessary, shall require the wearing of goggles with cups of soft pliable rubberem385.us and COGNIZENSE LLP are not connected or affiliated with NAVFAC, USACE the U.S. Department of Labor (DOL) or the Occupational Safety and Health Administration (OSHA). em385.us issues signed EM385-1-1 professional program and course completion certificates and transcripts to document a student’s training.EM 385-1-1 XX Jul 14 19-1 SECTION 19. Floating Plant and Marine Activities . 19.A General Requirements. 19.A.01 Floating plant inspection and certification. a. All floating plant regulated by the USCG shall have required USCG documentation that is current before being placed in service. A copy shall be posted in a public area on board the vessel.in conjunction with ER 385-1-80 and EM 385-1-1. Contractor requirements concerning ionizing and non-ionizing radiation protection issues are contained in EM 385-1-1. 1-3. Distribution Statement. Approved for public release; distribution is unlimited. 1-4. References. Appendix A contains a list of references used in this manual. 1-5. Policy. a.EM 385-1-1 30 Nov 14 27-3 d. Plumbing-up guys shall be removed only under the supervision of a Competent Person (CP). e. Measures shall be taken to prevent unrolled wire mesh from recoiling. 27.B. 03 Post-tensioning operations. a. No employee (except those essential to the post-tensioning operations) shall bestandardization of all safety programs. The EM 385–1–1 prescribes the safety and health requirements for all Corps of Engineers activities and operations. The USACE is soliciting comments on the proposed revisions to EM 385–1–1. USACE intends to update the manual and periodically thereafter, to reflect such public input, experience, EM 385-1-1 30 Nov 14 16-2 h. Operators of equipment with a maximum manufacturer -rated hoisting/lifting capacity of 2,000 pounds (907 kg) or less, are exempt from the operator qualification or certification requirements in Sections 16.B.02 through 16.B.05 only. In addition, this equipment may not be used to hoist personnel ; i. EM 385-1-1: CESO: Safety and Occupational Health (SOH) Requirements: 3/15/2024: EM 200-1-12: CEMP-CE: Environmental Quality: Conceptual Site Models: 8/11/2023: EM 5-1-11: CECW/CEMP: Project... Em385, This training fulfills the SSHO requirement to maintain his/her competency according to EM-385-1-1 Section 01.A.17d. This course includes the following objectives: - Discuss all recent revision changes of EM 385 1-1, 2014 - Explain why changes are required and how their application applies towards developing safe and healthful construction processes., This EM 385 training course is based off of, and complies with, the US Army Corps of Engineers EM 385-1-1 manual, and is compliant with the most recent 2014 revisions to that manual. This training, and the EM 385-1-1 manual, prescribes the safety and health requirements for all Corps of Engineers activities and operations. This., EM 385-1-1 XX Jul 14 21-4 . a. be trained appropriately; b. advise and provide guidance for managers, employees and others on all matters pertaining to their Fall Protection …, EM 385-1-1 XX Jul 14 22-7 (2) Where the employer makes the demonstration as described in 22.B.08(d)(1), the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 ½ in (24.1 cm). e. When planking is lapped in a long run, each plank shall lap its supports at ..., The new 40-hour EM 385-1-1 course is designed to provide comprehensive training on Safety and Occupational Health (SOH) Requirements based on the updated EM 385 manual, effective March 2024. This online course covers the latest regulations and guidelines outlined in the updated manual. The course has been expanded to include …, www.publications.usace.army.mil, EM 385-1-1 (2014) Contractor Safety. OSHA definitions changed for Confined Space in construction. 01.A.12 Accident Prevention Plan (APP) for Contract Work. Before initiation …, The most current revision of EM-385-1-1, Section 21.C.04a mandates that starting in May 2016 the Competent Person for Fall Protection shall attend a minimum of 24 hours fall protection training with a combination of formal classroom training …, DEPARTMENT OF THE ARMY EM 385-1-1 U.S. Army Corps of Engineers CESO-ZA Washington, D.C. 20314-1000 For sale by the U.S. Government Printing Office Superintendent of Documents, Mail Stop: SSOP, Washington, DC 20402-9328 ISBN 0-16-048877-x Manual No. 385-1-1 3 November 2003 Safety SAFETY AND HEALTH REQUIREMENTS 1. , This manual applies to Headquarters, US Army Corps of Engineers (HQUSACE) elements, major subordinate commands, districts, centers, laboratories, and field operating activities (FOA), as well as... , EM 385 Training. 24 Hours 15 Modules. Details. Beginner. Free Course Environmental Management Systems (5.00) CSP Exam Prep. 6 Modules. Details. Proficient. Free Course Ergonomics (5.00) ASP Exam Prep. 6 ..., EM385 and USACE Compliant Competent Person Training. Ellis Fall Safety Solutions is the premier destination for Army Corps of Engineers Fall Protection training courses, specifically EM 385-1-1 training. With over 50 years of experience in Working at Heights and Fall Safety training and regulations, our tailored three-day (24-hour) EM 385 ..., We would like to show you a description here but the site won’t allow us., This complete EM 385-1-1 training course is 40 hours. However, don’t let that scare you. All TITAN University Courses can be taken wherever you want, whenever you want, as long as you can connect to the internet. You can stop and start whenever you like and we’ll save your place. In addition, students can also choose to take 8-Hour EM 385 ..., EM 385 training gives you the knowledge needed to successfully win a bid for government construction work. In many cases, your bid will be rejected if it does not include a site-specific safety plan that meets all EM 385-1-1 requirements. OSHA Pros is dedicated to providing helpful information and OSHA training courses for contractors and more., 5) Temporary Facilities. 6) Personal Protective and Safety Equipment. 7) Toxic Agents & Environments. View More Module. Price: $49.99. Add To Cart. Best Price Online EM 385 Training, Access 24/7 On All Devices. Easy To Take, Money Back Guarante., must be familiar with the requirements of EM 385-1-1 and have experience in the areas of hazard identification and safety compliance. The individual must be capable of interpreting a critical path schedule and construction drawings. The qualification requirements for the alternate superintendent are the same as for the project superintendent. The, EM 385-1-1 30 Nov 14 14-5 14.C.05 Material storage shall be in compliance with manufacturer’s recommendations. 14.C.06 Materials stored inside buildings under construction shall not be placed within 6 ft (1.8 m) of any hoistway or floor opening, or within 10 ft (3 m) of an exterior wall that does not extend above the material s stored. , ConTRactor Safety. The Fall Protection Field Guide is available in Android and Apple platforms, download to your mobile device today. The guide is based on the EM385-1-1 and provides guidance on how to apply the requirements. The EM385-1-1 (Safety and Health Requirements Manual) is available as an app for smartphones., DEPARTMENT OF THE ARMY EM 385-1-1 ‌. U.S. Army Corps of Engineers. CESO-ZA Washington, D.C. 20314-1000. Manual. No. 385-1-1 30 November 2014. Safety. SAFETY AND HEALTH REQUIREMENTS. Purpose. This manual prescribes the safety and health requirements for all Corps of Engineers activities and operations. , EM 385-1-1 30 Nov 14 5-4 05.B.05 Operations that require handling of harmful materials (e.g., acids, caustics, hot liquids, or creosoted materials) and operations where protection from gases, fumes, and liquids is necessary, shall require the wearing of goggles with cups of soft pliable rubber, EM 385-1-1 training provides an orientation to regulations and guidelines outlined in the U.S. Army Corps of Engineers Safety and Health Manual, also known as the EM 385-1-1 Manual. Your online training will cover EM 385-1-1 safety and health requirements, including hazard recognition techniques that will prepare you to avoid injuries on the job. , This course is the first of five parts in the 40-hour Hazard Awareness Course for Contractors. It covers requirements detailed within the first 6 sections of EM 385-1-1 (2014). The 5-course program will help all managers, supervisors, contractors, or construction personnel working on U.S. military contracts and any worker needing to be ..., EM 385-1-1 30 Nov 14 . 10-5 . e. Workers may be exposed to hazardous concentrations of chromium (VI) while welding, cutting or performing hot work on stainless steel, high chrome alloys or chrome-coated metal, or during the application and removal of chromate-containing paints and other surface coatings. > See Section 06.L. f., EM 385-1-1 30 Nov 14 34-2 (2) If it is known that work to be conducted inside a CS would create a possible hazardous atmosphere, the contractor shall be notified prior to beginning work and shall be required to follow the requirements for PRCS . (3) All entry into an identified or contractor-created PRCS shall be coordinated with the, EM 385-1-1 XX Jul 14 22-4 c. Be readily visible. legible and made from materials that will withstand the elements; d. Include wording that states one of the following: (1) Scaffold is complete and safe to use; (2) Scaffold is incomplete, not ready for use and reasoning, or (3) Scaffold is incomplete and unsafe to use. , 5) Temporary Facilities. 6) Personal Protective and Safety Equipment. 7) Toxic Agents & Environments. View More Module. Price: $49.99. Add To Cart. Best Price Online EM 385 Training, Access 24/7 On All Devices. Easy To Take, Money Back Guarante., Apr 14, 2022 · SUMMARY: The U.S. Army Corps of Engineers (USACE) Safety and Health Requirements Manual (EM 385–1–1) is the gold standard for Safety and Occupational Health regulations. The manual holds a long history dating back to 1941 and is designed to facilitate the standardization of all safety programs. The EM 385–1–1 prescribes the safety and ... , EM 385-1-1 XX Jul 14 5-1 SECTION 5 . Personal Protective and Safety Equipment . 05.A General Requirements. 05.A.01 Responsibilities. a. The use of personal protective and safety equipment (PPE) is a control measure that is to be used only after a hazard evaluation identifies hazards associated , This course is designed for facility and site supervisors who must also serve as the competent person required by EM385-1-1 Army Corp of Engineers requirements. The training provides detailed coverage of fall prevention and protection, roles of the worker, building a fall protection system, pre-use and component person inspection, and …, CICB Senior Instructor Larry Kime introduces us to EM385-1-1. Larry reminds us that contractors on a military installation must be aware of more than the OSHA regulations and ANSI/ASME standards. US Army Corps of Engineers (USACE) EM385-1-1 is a broad range safety standard written into any contract for contractors on a military installation. , The EM-385-1-1 manual is vital in getting and maintaining work on government contracts. It includes all safety and health requirements for all Corps of Engineers activities and operations, including Naval Facilities Engineering Command (NAVFAC) construction and Department of Defense projects. This edition replaces the …, 8-Hour EM 385-1-1 Refresher Training. The 8-Hour EM 385-1-1 online refresher course is designed to keep Site Safety Health Officers (SSHOs), military contractors and government employees compliant with annual refresher training requirements from the U.S. Army Corps of Engineers. $99.